LOG SPLITTER MODEL NO: LOGBUSTER 6 PART NO: 3402035 OPERATION & MAINTENANCE INSTRUCTIONS 10/08
INTRODUCTION Thank you for purchasing this CLARKE product. Before attempting to use this product, please read this manual thoroughly and follow the instructions carefully. In doing so you will ensure the safety of yourself and that of others around you, and you can look forward to your purchase giving you long and satisfactory service. GUARANTEE This product is guaranteed against faulty manufacture for a period of 12 months from the date of purchase.
CONTENTS Introduction ................................................................................ 2 Guarantee .................................................................................. 2 In the box .................................................................................... 2 Contents...................................................................................... 3 General safety rules ..................................................................
GENERAL SAFETY RULES WARNING: READ ALL INSTRUCTIONS. FAILURE TO FOLLOW ALL INSTRUCTIONS LISTED BELOW MAY RESULT IN ELECTRIC SHOCK, FIRE AND/ OR SERIOUS INJURY. SAVE THESE INSTRUCTIONS. WORK AREA 1. Keep the work area clean and well lit. Cluttered and dark areas invite accidents. 2. Do not operate log splitters in explosive atmospheres, such as in the presence of flammable liquids, gases or dust. Log splitters create sparks which may ignite the dust or fumes. 3.
USAGE AND CARE 1. Do not force the log splitter. It will do the job better and safer at the rate for which it was designed. 2. Disconnect the plug from the power source before making any adjustments, changing accessories, or storing the log splitter. Such preventive safety measures reduce the risk of starting the log splitter accidentally. 3. Storethe log splitter out of the reach of children and do not allow persons unfamiliar with log splitters or these instructions to operate the log splitter.
12. Never use the log splitter if it is damaged or if it needs servicing. 13. Before starting work, check correct functioning of all the safety devices and check for soundness of welded joints, securing nuts & bolts. SIZE OF THE LOGS BEING SPLIT The image on the right shows the maximum log size that can be split. • Do not attempt to split a log for longer than 5 seconds as the pump may be damaged by the oil overheating.
SAFETY SYMBOLS 7
ELECTRICAL CONNECTIONS Connect the mains lead to a standard, 230 Volt (50Hz) electrical supply through an approved 13 amp BS 1363 plug, or a suitably fused isolator switch.
IDENTIFICATION OF PARTS No Description Part number No Description Part number 1 Ram travel adjusting rod LGLOGB601 10 Oil tank cover / air bleeder LGLOGB610 2 Transport handle LGLOGB602 11 Wheels LGLOGB611 3 Split wedge LGLOGB603 12 Base LGLOGB612 4 Control levers connection bracket LGLOGB604 13 Star knob LGLOGB613 5 Top motor shield LGLOGB605 14 Side bracket for support table LGLOGB614 6 Plug & switch LGLOGB606 15 Table lock down hook LGLOGB615 7 Ram LGLOGB607 1
ASSEMBLY FITTING THE CONTROL ARMS 1. Position the control lever into the side of the arm assembly as shown. • Make sure the control lever goes into the slot on the arm assembly. 2. Lock the arm assembly in to position with the bolt, large washer, small washer and nut supplied. 3. Follow the same steps to install the other arm assembly. FITTING THE WHEELS 1. Slide one of the wheels onto the axle followed by a washer. 2. Slide the axle through the holes on the frame as shown on the right. 3.
FITTING THE SUPPORT TABLE There are 3 positions available for the support table to accomodate different log lengths. 1. Insert the support table arms into both side brackets. 2. Insert the star knob to lock the support table into position. • The star knob can be fitted on either side of the bracket. MOVING THE LOG SPLITTER CAUTION: BEFORE MOVING THE LOG SPLITTER, MAKE SURE THE OIL TANK COVER / AIR BLEEDER IS FULLY TIGHTENED TO AVOID OIL LEAKAGE. To move the log splitter to the work site. 1.
OPERATION PREPARATION • Plan your work before hand. Have your logs positioned where they can be easily reached. • Route the cord from the power source to the splitter in a way that safeguards against tripping on the cord, or the cord becoming damaged during the work session. Protect the power cord from impact, tugging or contact with corrosive materials. LOGS • When cutting up limbs and large sections, do not cut sections any longer than 1050 mm. • Do not attempt to split green logs.
INSERT THE MAINS LEAD 1. Insert the adapter plug into the socket shown on the right. 2. Insert the mains plug into the mains power supply and switch on. TURNING THE LOG SPLITTER ON/OFF While operating under extremely low temperature, turn on the log splitter on 15 minutes before use to preheat the hydraulic oil. 1. Lift up the flap on the switch housing to access the on/off buttons. 2. Press the ON button ( I ) to turn the logbuster on. 3. Press the OFF button ( 0 ) to turn the logbuster off. 4.
SPLITTING A LOG This log splitter is designed to be operated by one person only and requires two handed operation by the user CAUTION: SPLIT LOGS IN THE DIRECTION OF THE GRAIN. DO NOT PLACE LOGS ACROSS THE LOG SPLITTER FOR SPLITTING. IT MAY BE DANGEROUS AND MAY SERIOUSLY DAMAGE THE MACHINE. 1. Place the log onto the support table vertically making sure that it is sitting flat on the support table. • Ensure the wedge will come into contact with the log squarely on the end.
ADJUSTMENTS TO SET WEDGE RAM STROKE Adjusting the ram stroke will set the height which the ram will return to, when you release the control levers. 1. Press down on both control levers until the splitting wedge is at the desired height. • The upper position of the ram wedge should be about 3-5 cm above the logs being split. 2. Release one control lever and then switch off the motor. • The ram will remain in its current position. 3. Release the locking screw. 4.
MAINTENANCE WARNING: MAKE SURE THAT THE LOG SPLITTER IS SWITCHED OFF AND DISCONNECTED FROM THE MAINS SUPPLY BEFORE STARTING ANY CLEANING OR MAINTENANCE PROCEDURES. HYDRAULIC OIL The hydraulic system is a closed system with an oil tank, oil pump and control valve. • Check the oil level regularly using the dipstick attached to the oil tank cover / air bleeder. TO TOP UP THE HYDRAULIC OIL 1. Remove the oil tank cover / air bleeder completely. 2.
TROUBLESHOOTING PROBLEM CAUSE REMEDY Motor does not start. No power being supplied Check mains fuse Extension lead is defective Unplug, check and replace if necessary Switch is defective Return the unit to your local Clarke dealer for servicing. Air bleeder is not open Open oil bleeder. Control levers are bent Repair the bent control levers Low oil level Check and refill hydraulic oil. Low oil level Check and refill hydraulic oil. Log splitter does not work while the motor is running.
SPECIFICATIONS Logbuster 6 Electrical Supply 230V @ 50Hz Input Wattage 3000 W Part Number 3402035 Maximum Force 5.
DECLARATION OF CONFORMITY 19