LOG SPLITTER MODEL NO: LOGBUSTER 5 PART NO: 3402030 OPERATION & MAINTENANCE INSTRUCTIONS LS0109
INTRODUCTION Thank you for purchasing this CLARKE Log Splitter. Before attempting to use this product, please read this manual thoroughly and follow the instructions carefully. In doing so you will ensure the safety of yourself and that of others around you, and you can look forward to your purchase giving you long and satisfactory service. GUARANTEE This product is guaranteed against faulty manufacture for a period of 12 months from the date of purchase.
GENERAL SAFETY RULES WARNING: READ ALL INSTRUCTIONS. FAILURE TO FOLLOW ALL INSTRUCTIONS LISTED BELOW MAY RESULT IN ELECTRIC SHOCK, FIRE AND/ OR SERIOUS INJURY. SAVE THESE INSTRUCTIONS. WORK AREA 1. Keep the work area clean and well lit. Cluttered and dark areas invite accidents. 2. Do not operate log splitters in explosive atmospheres, such as in the presence of flammable liquids, gases or dust. Log splitters create sparks which may ignite the dust or fumes. 3.
USAGE AND CARE 1. Do not force the log splitter. It will do the job better and safer at the rate for which it was designed. 2. Disconnect the plug from the power source before making any adjustments, changing accessories, or storing the log splitter. Such preventive safety measures reduce the risk of starting the log splitter accidentally. 3. Storethe log splitter out of the reach of children and do not allow persons unfamiliar with log splitters or these instructions to operate the log splitter.
8. Split wood in the direction of the grain. Do not attempt to split a piece of wood across the grain as this could seriously damage the machine. 9. If the log moves away from the blade, retract the ram and rotate the log through 90O as shown on the right. 10. Do not attempt to load the log in the machine whilst the log pusher is in motion. 11. Keep your hands well away from any splits and cracks which open in the log. 12.
SAFETY SYMBOLS 6
ELECTRICAL CONNECTIONS Connect the mains lead to a standard, 230 Volt (50Hz) electrical supply through an approved 13 amp BS 1363 plug, or a suitably fused isolator switch.
IDENTIFICATION OF PARTS No Description Part number No 1 Log pusher LGLOGB501 8 Motor LGLOGB508 2 Work table LGLOGB502 9 Switch box LGLOGB509 3 Wedge LGLOGB503 10 Wheels LGLOGB510 4 Lifting handle LGLOGB504 11 Control lever LGLOGB511 5 Support leg LGLOGB505 12 Guard LGLOGB512 6 Log retaining plates LGLOGB506 13 Bleed screw LGLOGB513 7 Push button switch LGLOGB507 14 Oil Drain bolt with dipstick LGLOGB514 8 Description Part number
BEFORE USE BLEEDING THE HYDRAULIC SYSTEM Before operating the log buster, the Bleed Screw should be loosened by 2-3 turns until air can go in and out of the oil tank smoothly. Bleed Screw • Air flow through the Bleed Screw hole should be detectable when the log buster is in operation. Before moving the log buster, make sure the Bleed Screw is tightened to avoid oil leaking from this point. WARNING: FAILURE TO DO THIS WILL CAUSE PERMANENT DAMAGE TO THE LOG BUSTER.
OPERATION OPERATING THE LOG BUSTER This log buster is designed to be operated by one person only and requires two handed operation by the user The left hand controls the hydraulic control lever and the right hand controls the push button switch. 1. Push and hold the push button switch 2. Then press and hold down the control lever to start the log buster. • The log buster will freeze if either control is released. • When both controls are released, the log pusher returns to the starting position.
FREEING A JAMMED LOG 1. Release both controls. • The log pusher moves back and completely stops at its starting position. 2. Insert a wedge wood under the jammed log. 3. Start the log buster to push the wedge wood to go completely under the jammed one. 4. Repeat above procedure with sharper sloped wedges of woods until the log is completely free. Do not try to hit the jammed log off of the log buster, this may damage the machine or may cause the log to fly up and cause an accident.
MAINTENANCE WARNING: MAKE SURE THAT THE LOG SPLITTER IS SWITCHED OFF AND DISCONNECTED FROM THE MAINS SUPPLY BEFORE STARTING ANY CLEANING OR MAINTENANCE PROCEDURES. REPLACING THE HYDRAULIC OIL Replace the Hydraulic oil in the log buster after every 150 hours of use. Take following steps to replace it. 1. Place a container, large enough to hold 4 liters of oil under the oil filler plug, Loosen the bleed screw three or four turns. 2.
TRANSPORT AND STORAGE MOVING THE LOG BUSTER CAUTION: BEFORE MOVING THE LOG BUSTER, MAKE SURE THE BLEED SCREW IS TIGHTENED TO AVOID OIL LEAKING. • Lift the front of the log buster by the handle and move the log buster to the woking area. STORAGE When you have finish working with your log buster 1. Disconnect the log buster from the mains supply. 2. Tighten the bleed screw. 3. Clean the unit down using a dry cloth. TROUBLESHOOTING PROBLEM CAUSE REMEDY Fails to split logs Log is improperly positioned.
SPECIFICATIONS Logbuster 5 Electrical Supply 230V @ 50Hz Input Wattage 2000W 3402030 Part Number IP Rating IP54 Weight 44.
DECLARATION OF CONFORMITY 15