Operator`s manual
Clarke
®
Ext- 311 Owner's Manual Page 11
MAINTENANCE (CONT)
How To Prevent Damage From Freezing Temperatures
To prevent damage from freezing temperatures follow this
procedure:
1. Use the vacuum hose to remove all the solution from
the clean solution tank.
2. Connect the solution hose to the extractor and a floor
tool.
3. Put approximately 1 quart of antifreeze solution in the
solution tank.
4. Put the switch for the pump in the "I" position.
5. Put the end of the floor tool in the recovery pail.
6. Press the lever on the floor tool to activate the pump.
7. Make sure the solution runs through the system.
8. Release the lever on the floor tool to stop the pump.
9. Flush the antifreeze solution from the system before
using the extractor.
WARNING: Electrical repairs must be done by
authorized personnel only.
WARNING: After electrical repairs are done to the
machine, the machine must be tested
for electrical safety.
How To Get Access To The Pump and Vacuum Motor
To get access to the pump and the vacuum motor, follow
this procedure:
1. Remove the dome.
2. Empty both tanks.
3. Remove the pail.
4. Remove the ten screws from the lower housing (1).
5. Lift the upper housing from the machine (2).
See figure 10.
Figure 10
1
2