Specifications

MAINTENANCE
It is essential that the heater is correctly maintained and kept in top condition at all times.
IMPORTANT
Before carrying out any adjustment or maintenance, ensure the heater is
switched OFF, disconnected from the mains and gas supply’s, and has been
given adequate time to cool down.
All models are similar, in that access to the working parts, is gained by removing
the rear panel, which is secured by 4 screws, (3 in the case of the Little Devil),
around its’ edge. Once removed, the panel complete with all components may
be lifted clear.
Monthly (When in constant use)
Ensure the electrode is clean, and the gap is no more than 5mm (see fig 4).
Check the condition of the gas hose, if there are any signs of deterioration, it
should be renewed, using only a CLARKE original spare part.
Ensure that all connections are clean and firm.
When necessary, clean the fan and inside of the heater thoroughly.
SPECIFICATIONS
Little Devil Devil Devil Devil Devil
Devil 650 850 1250 1850 3150
Min. Output (Btu/hr) - - 24,000 60,500 83,350 198,000
Max. Output (Btu/hr) 34,000 60,000 78,500 121,000 170,000 300,000
Gas Pressure Max (bar/psi) 0.3/5 0.7/10 1.5/22 1.5/22 1.5/22 2/30
Air Flow (m
3
/hr) 300 300 650 650 1,500 3300
Gas Consumption (kg/hr) 0.8 1.35 0.6 - 1.8 1.4 - 2.8 2 - 4 4.6 - 8.3
Nozzle Size (mm) 0.7 1.00 1.1 1.25 1.5 2.0
Motor Voltage (Volts) 230 -1ph 230 -1ph
110/230-1ph
230 -1ph 230 -1ph 230 -1ph
Power rating (Watts) 35 35 85 85 91 140
Input Current 230V (Amps) 0.26 0.3 0.7 0.35 0.42 0.5
110V (Amps) 0.3
Fuse Rating (Amps) 13 13 13 13 13 13
Dimensions (mm)
350x180x270 490x180x270 550x270x320 635x270x380 725x460x535
1075x420x565
Weight (kg) 5 6 13 15.5 23 30
Part No. 6920160 6920162 6920170 6920340 6920360 6920350
10