DEVIL CERAMIC SPACE HEATERS Devil 330 Part Nos: 6920264 (110V) & 6920265 (230V) OPERATING & MAINTENANCE INSTRUCTIONS GC0310
INTRODUCTION Thank you for purchasing this CLARKE Ceramic Space Heater. Please read this manual thoroughly and follow the instructions carefully. Before attempting to use the heater, thoroughly familiarise yourself with the heater & its operation. In doing so you will ensure the safety of yourself and that of others around you, and you can look forward to the heater giving you long and satisfactory service.
GENERAL SAFETY RULES 1) WORK AREA 1. These heaters are for INDOOR USE ONLY. 2. Do not expose the heater or power cable to rain or wet conditions. Any water entering the heater will increase the risk of electric shock. DO NOT use this heater in a bathroom, shower room or any other wet environment. 3. NEVER locate the heater near combustible materials such as curtains, furniture etc. Allow at least 2 metre distance. 4. DO NOT locate the heater close to an adjacent wall or low ceiling.
. ALWAYS disconnect from the mains supply before moving the heater, or performing any cleaning or maintenance tasks. 5. Inspect the mains cable regularly for signs of damage. DO NOT use if it is damaged, and ALWAYS keep it away from the source of heat. 6. Check the heater for damage before use. Any damage should be properly repaired or the part replaced. If in doubt, DO NOT use. Consult your local Clarke dealer. 3) SERVICE & REPAIRS 1.
If this appliance is found to be fitted with a plug which is moulded on to the electric cable (i.e. non-rewireable) please note: 1. The plug must be thrown away if it is cut from the electric cable. There is a danger of electric shock if it is subsequently inserted into a socket outlet. 2. Never use the plug without the fuse cover fitted. 3. Should you wish to replace a detachable fuse carrier, ensure that the correct replacement is used (as indicated by marking or colour code). 4.
UNPACKING AND ASSEMBLY Before assembling, please check contents against the following list and advise your dealer immediately if any parts are missing. 1 x Heater 2 x Support Legs 4 x Screws 1. Attach the side legs to the heater using the screws provided. 2. Fit the feet and end caps as shown. 3. DO NOT use the heater without fitting the legs. INSTRUCTIONS FOR USE 1. Place the heater on a firm, solid foundation, and following all safety precautions, plug in to a suitable mains supply. 2.
CLEANING & MAINTENANCE ALWAYS allow the heater to cool down for at least 15 minutes and disconnect from the mains supply before performing any maintenance tasks. PERIODICALLY • Inspect the mains cable for damage. Undue heat will cause the cable to stiffen and crack. If this is found, have the cable replaced. Check cable routing and ensure it is well away from the heat source. • Disconnect from the mains supply, remove the guard and wipe the reflector and elements with a clean damp cloth.
FAULT FINDING Problem Heater does not operate, although plugged in and switched on. Heating element glowing hot. Possible Cause Remedy Plug is loose/bad connection. Pull the plug out & check the connection of the plug and socket. Fuse blown Replace if necessary and investigate cause. If fuse blows re p e a t e d l y , c o n s u l t y o u r C L A R K E dealer. No power at socket outlet. Insert the plug in a suitable socket. Input voltage too high Use a power supply in or too low.
COMPONENT PARTS No Description Part No 1 Front Guard AX20240017 2 Screw 3 Front Panel 4 No Description Part No 13 Cable AX20390125 AX20230079 14 Cable AX20390126 AX20630985 15 Cable AX20390127 Heating Element AX20070016 16 Rubber Foot AX20020017 5 Side Reflector Panel AX20630023 17 Washer AX20230148 6 Main Reflector Panel AX20630022 18 Screw AX20230076 7 Rivet AX20230191 19 Foot AX20610024 8 Handle AX20010007 20 AX20320014 9 Rear Panel AX20630990 21 Cable Clam
TECHNICAL SPECIFICATION Model Devil 330 Part No 6920264 6920265 Weight 6 kg 6 kg Dimensions (LxWxH) mm 365x400x525 365x400x525 Max. Heat Output 800/1600/2400 W 800/1600/2400 W Rated Current 21.8 A 10.5 A Supply Voltage 110v / 50 Hz / 1ph 230v / 50 Hz / 1 ph Fuse rating 13 A 13 A Insulation Class IP20 IP20 Please note that the details and specifications contained herein, are correct at the time of going to print.
DECLARATION OF CONFORMITY 11