NORMAL RUNNING
The compressor is fitted with a combined ON/OFF pressure control switch
whose cut-in and cut-out pressures are factory set.
When the reservoir pressure falls below the minimum threshold setting, (about
2-bar lower than the maximum pressure) the compressor will re-start and will
cut out when the maximum reservoir pressure is achieved.
Note: If the machine pumps continuously without intermittently switching on
and off, the compressor is too small for the demand of the application/tool
being used and damage could result. Consult your Clarke dealer.
OVERLOAD CUT-OUT
The compressor is fitted with an
overload cutout to protect the
motor in the event of overheating.
If the device should trip out and
shut down the compressor, wait
around 5 minutes for the machine
to cool down before re-setting the
device by pressing the overload re-
set button shown in Fig 7.
If, having re-started the compressor,
the overload cutout trips again, set
the main switch to the OFF position,
unplug the machine and consult your Clarke dealer.
SHUTTING DOWN AND STORAGE
Press the red ON/OFF switch to shut off the compressor.
Never stop the compressor by unplugging it from the power supply. It should
be turned off as above.
After use, set the outlet pressure back to zero.
Trigger all equipment (tools, spraygun etc) to release any air pressure from the
air hose before disconnecting the hose from the compressor.
Before transporting or storing the compressor, release all air pressure from the
reservoir by opening the drain valve shown in Fig 1.
• It may be desirable to place a container beneath the compressor
to catch any condensate.
Avoid storing the compressor in an environment where the temperature is
likely to drop to or below freezing.