” ELECTRIC WATER PUMP MODEL NO: BIP1500 PART NO: 7230335 OPERATION & MAINTENANCE INSTRUCTIONS LS0714
INTRODUCTION Thank you for purchasing this Clarke Water Pump. Before attempting to use this product, please read this manual thoroughly and follow the instructions carefully. In doing so you will ensure the safety of yourself and that of others around you, and you can look forward to your purchase giving you long and satisfactory service. DESCRIPTION This non-submersible centrifugal pump is designed to pump clean water in gardens for spraying and irrigation purposes and for pumping water to greenhouses.
GENERAL SAFETY PRECAUTIONS Before using this equipment it is in your own interest to read and pay attention to the following safety rules. WARNING: ALWAYS CONNECT THE PUMP TO AN EARTHED POWER SUPPLY VIA AN RCD. 1. ALWAYS keep the working area clean and well lit. Floors should always be kept clear. Cluttered or dark areas invite accidents. 2. NEVER over-reach. Keep your proper footing and balance at all times when installing or maintaining the pump. 3.
INSTALLATION Because of the number of possible installations, no accessories are supplied with your pump, however accessories are available from your nearest Clarke dealer. See the suggested list on page 13. NOTE: It is recommended that the end user should consult a qualified installer if there are any doubts as to the suitability of this product for a particular installation. IMPORTANT: The pump MUST NOT be connected to the mains power supply until all hose/pipe installation is completed.
FITTING THE CABLE Do not attempt electrical installation work if you are in any doubt as to how it should be done correctly. Consult a qualified electrician. The pump must be wired according to the diagram, after removing the cover plate, ensuring the following principles are observed: • The cable used must be the correct size to ensure it is a tight fit in the cable gland. • Ensure the cable gland is correctly used. The clamp must firmly hold the outer cable sheath and not the wires.
. Plug must be BS1363/A approved. Always fit a 13 Amp fuse. Earth (Green and Yellow) Live Neutral (Brown) (Blue) Ensure that the outer sheath of the cable is firmly held by the clamp • Before switching the product on, make sure that the voltage of your electricity supply is the same as that indicated on the rating plate. This product is designed to operate on 230VAC 50Hz. Connecting it to any other power source may cause damage.
The performance of your pump will be affected by the diameter of the inlet pipe - any restriction will greatly reduce the flow. We recommend that you always use a pipe diameter at least equal to, or greater than the diameter of the pump connections. To prevent unnecessary strain ensure that adequate support is provided to the hoses and pipes. They will be considerably heavier when filled with water. It is suggested that suction and delivery isolation valves are fitted in order to isolate the pump.
PRIMING THE PUMP Before pumping, you must completely fill the suction side with water to prime the pump which is carried out as follows:1. With all inlet pipes/hoses and foot valve in position, but no outlet hose connected, pour water into the outlet port until all the air is expelled. 2. Connect the outlet hose to the outlet port. If the outlet hose is already connected, a priming hole and threaded plug are provided, adjacent to the outlet as shown.
OPERATION 1. Open any valves in the pipeline. 2. If operating the pump for the first time, prime the pump as described. NOTE: The pump is only self-priming when filled with water. Refilling is only necessary if the pump has been drained, or if all the water has been lost. 3. Connect to the power supply and switch on. Water should start to flow through the system. Check for any leaks and make good as necessary. • If the motor fails to start, or the pump does not deliver water, refer to TROUBLESHOOTING.
MAINTENANCE The only maintenance required is a regular inspection to ensure that debris is not blocking the passage of water through the pump. If you suspect the pump is blocked by silt, leaf debris etc, disconnect it from the power supply and back-flush to clear any blockage using a hose. You will need to disconnect the outlet hose to do this. Always keep the pump in a clean condition, checking regularly for loose bolts or a damaged power cable etc.
TROUBLESHOOTING Problem Cause Solution Pump does not run. Thermal protection has been activated. If the motor has overheated, wait for it to cool down before trying again. Faulty power connection Insert plug securely. Pump fails to prime No mains supply Check fused power supply and replace fuse if necessary (check fuse rating). Check circuit breaker Impeller seized/blocked Disconnect pump from power supply.
High friction losses in the suction line. Avoid unnecessary curves, restrictions or valves Pump badly sited result- Set pump as close as ing in suction lift too high possible to the level of the water to be pumped Sudden loss of flow. Blockage of inlet pipe Undue vibration or noise. Excessive flow of water. Check pipeline for blockage. Decrease flow of water. by adjusting inlet/outlet valves in system. Resistance in inlet pipe caused by obstruction.
SPECIFICATION Water Classification Clean Maximum Delivery 45 l/min Maximum Head 50 m Maximum Suction Lift 7m Operating Temperature 0-40oC Ingress Protection Rating IPx5 Supply 230V / 50Hz Rated Power 800W Input Current@ Maximum Head 3.56 A Outlet Thread Size 1” BSP Weight 8.6 kg Length x Width x Height 298 x 140 x 196 mm Sound Pressure Level 65 dB LpA Sound Power Level 77 dB LwA Guaranteed Sound Power Level 79 dB LwA Uncertain Factor 2.
PARTS DIAGRAM ID DESCRIPTION PART NO ID DESCRIPTION PART NO 1 Screw ZGBIP150001 16 ZGBIP150016 2 Pump Body ZGBIP150002 17 Power Cable ZGBIP150017 3 Impeller ZGBIP150003 18 Terminal Box Screw ZGBIP150018 4 O Ring ZGBIP150004 19 Cable Seal ZGBIP150019 5 Motor Front Cover ZGBIP150005 20 Terminal Box ZGBIP150020 6 Ball Bearing ZGBIP150006 21 Power Switch ZGBIP150021 7 Motor Rotor ZGBIP150007 22 Terminal Box Cover ZGBIP150022 8 Stator Coil ZGBIP150008 23 Screw Z
DECLARATION OF CONFORMITY 15 Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.