Specifications

20
TORCH BODY, HANDLE AND CABLE
These parts need no particular maintenance with the exception of a periodic
inspection and cleaning
To keep the torch and the cable in good working order it is necessary to follow
these precautions:
DO NOT use solvents or strong detergents when cleaning the plasma
cutter.
If there is damage to the insulation such as breaks, cracks and burns
or even a loosening of electric conductors, the torch must not be
used.
DO NOT touch torch and cable with warm or hot parts.
DO NOT strain the cable.
DO NOT move the cable on sharp edges or abrasive surfaces.
DO NOT step on the cable.
All repairs must be carried out buy a qualified service engineer.
COMPRESSED AIR FILTER
The unit is equipped with a filter for the compressed air. This filter is fitted with a
knob for the manual drain of the condensation. Purge periodically to remove
the water/oil in the filter by following the instructions below.
MANUAL PURGE
Oil in the air is a severe problem
and must be avoided.
The unit is equipped with an air
filter which captures water and
oil vapor.
The vapor collected can be
drained out by turning the drain
knob located on the bottom of
the air filter.
The drain knob has 3 positions: -
Open, Automatic (Open when no air pressure, closed when air pressure.) or
closed
The drain knob should be closed during cutting operations (position 2 or 3).
REPLACING THE AIR FILTER
The air filter and air filter cartridge can only be replaced by a qualified service
engineer, contact your nearest Clarke service department See page 3.