User manual

Troubleshooting
The Memorized Positions
are not correct.
First, try re-sync to correct the position.
If the symptom recurs repeatedly, replace
the reed sensor to see whether it is OK.
The LED displays |------ or
------| and can’t move any
farther.
The symbols mean electrical limits, which have been
set. To cancel this setting, use the “Limit Off” function
on the receiver or press the limit key for more than 10
seconds. The LED will show “|- - - - - -|” when it is
clear.
The LED lights but the
positioner doesn’t work (no
response).
Unplug the AC power. Wait for more than 10
seconds then reconnect it.
Unstable AC power can cause this problem. To
protect the stored data, the positioner will lock
itself in this situation. A voltage regulator or UPS
might be needed.
The manual
3
3344
4
buttons
drive for only 1 count.
These buttons are for fine-
tuning only, and the receiver
doesn’t support this function.
Specification
Input Voltage : 220-240VAC 60Hz
13 / 18 VDC (F Type via Coaxial Cable)
Output Voltage : 13 / 18 VDC (F Type / According to the Input)
36VDC (via Motor Cable)
Output Power : 60 W (Rated / Motor Cable)
Maximum Current : 3A
Power Consumption : 5W (Standby) 90W (Maximum)
Position Memories : 99
Protocol : DiSEqC 1.2
Operating
Temperature
:
5°C to 40°C (41°F to 104°F)
Storage Temperature :
-20°C to 60°C (-4°F to 140°F)
Dimensions (WxHxD) :
230x65x165 mm
3
(Net)/260x70x210 mm
3
(Gross)
Weight : 1.6 Kg (Net) / 1.8 Kg (Gross)
Symptoms
Check points
Imported and distributed by satmedia GmbH Germany www.satmedia.com