User's Manual
Table Of Contents
- About This Manual
- About the Clarius Ultrasound Scanner
- Using the Clarius Ultrasound Scanner
- Accessories
- Cleaning & Disinfecting
- Safety
- References
- Measurement Accuracy Tables
- Acoustic Output Tables
- Clarius Scanner C3 HD3: B-Mode
- Clarius Scanner C3 HD3: Color Doppler Mode
- Clarius Scanner C3 HD3: M-Mode
- Clarius Scanner C3 HD3: PW Doppler Mode
- Clarius Scanner C7 HD3: B-Mode
- Clarius Scanner C7 HD3: Color Doppler Mode
- Clarius Scanner C7 HD3: M-Mode
- Clarius Scanner C7 HD3: PW Doppler Mode
- Clarius Scanner EC7 HD3: B-Mode
- Clarius Scanner EC7 HD3: Color Doppler Mode
- Clarius Scanner EC7 HD3: M-Mode
- Clarius Scanner EC7 HD3: PW Doppler Mode
- Clarius Scanner L7 HD3: B-Mode
- Clarius Scanner L7 HD3: Color Doppler Mode
- Clarius Scanner L7 HD3: M-Mode
- Clarius Scanner L7 HD3: Needle Enhance B-Mode
- Clarius Scanner L7 HD3: Ocular (Ophthalmic) B-Mode
- Clarius Scanner L7 HD3: PW Doppler Mode
- Clarius Scanner L15 HD3: B-Mode
- Clarius Scanner L15 HD3: Color Doppler Mode
- Clarius Scanner L15 HD3: M-Mode
- Clarius Scanner L15 HD3: Needle Enhance B-Mode
- Clarius Scanner L15 HD3: Ocular (Ophthalmic) B-Mode
- Clarius Scanner L15 HD3: PW Doppler Mode
- Clarius Scanner L20 HD3: B-Mode
- Clarius Scanner L20 HD3: Color Doppler Mode
- Clarius Scanner L20 HD3: Ocular (Ophthalmic) B-Mode
- Clarius Scanner L20 HD3: M-Mode
- Clarius Scanner L20 HD3: Needle Enhance B-Mode
- Clarius Scanner L20 HD3: PW Doppler Mode
- Clarius Scanner PA HD3: B-Mode
- Clarius Scanner PA HD3: Color Doppler Mode
- Clarius Scanner PA HD3: M-Mode
- Clarius Scanner PA HD3: PW Doppler Mode
- Clarius Scanner PA HD3: Transcranial B-Mode
- Clarius Scanner PA HD3: Transcranial Color Doppler Mode
- Clarius Scanner PA HD3: Transcranial M-Mode
- Clarius Scanner PA HD3: Transcranial PW Doppler Mode
- Revision History
Clarius Ultrasound Scanner - HD3 Scanners Maintenance
revision 1 29
You can continue scanning patients while the scanner charges via the Fan. Use only power
supplies recommended by Clarius when plugging into an AC power outlet.
Do not charge the scanner via the Fan in air ambulances, regular ambulances, or the EMS
environment in general (including patient transportation and home healthcare).
Maintenance
The scanner routinely performs automated maintenance of the scanner itself. Prior to and
after use, you must clean and disinfect the Clarius Scanner HD3 according to the instructions in
this User Manual.
Perform maintenance regularly and as needed. The system must be serviced by trained
personnel only.
Failing to regularly maintain or verify the Clarius Ultrasound Scanner may lead to undetected
performance errors.
Hardware Maintenance
Testing Scanners
When you turn on the system, the scanner powers up and automatically tests its internal
components. The Clarius Scanner HD3’s LED will light up and you will hear a two-tone beep.
For a list of status lights and audible notifications, see Scanner Notifications on page 24.
Also, the system runs a series of tests in the background. If your smart device is not connected
to a wireless or cellular network, the logs are queued until you have network connectivity. For
more information, go to clarius.com/contact and contact Clarius.
Storing Scanners
To protect your Clarius Scanner HD3:
• Dry them thoroughly before storage.
• Avoid storing them in extreme temperatures.
• Avoid placing them under direct sunlight for prolonged periods of time. This will not
impact the Clarius Scanner HD3’s safety and performance but may discolor the housing's
finish.
• Store them separately from other equipment.