User`s guide
WN-5220-V VideoWall User’s Guide
47
1. Turn off the power
Switch off the WN-5220-V using the remote and allow the cooling cycle
to complete (3 – 4 minutes) before switching off the AC power at the
rear-panel switch.
2. Unplug power cord
Remove the AC power cord from the WN-5220-V.
3. Remove screen or
lamp access cover
To gain access to the lamp from the front of the VideoWall, remove the
screen first.
To gain access to the lamp from the rear of the VideoWall, unfasten the
8 quarter-turn screws on the lamp access cover and remove the cover.
4. Unplug lamp
connector
The lamp connector is next to the reflector fan. Unplug the connector by
pulling up on it.
5. Unhook the lamp
Unhook the two latches holding the lamp module to the optical
assembly.
6. Remove the lamp
Lifting up on the handle, tilt the lamp module away from the latches until
it can be pulled free of the optical assembly.
Carefully remove from the VideoWall by lifting the lamp module straight
up to clear the fans, and then withdrawing.
7. Install new lamp
Replacement is the reverse of the above procedure. After installing the
lamp module, ensure that the high-voltage connector is in place and that
the latches are securely latched before replacing the screen or the lamp
service access cover.
8. Reset the Lamp Hours
Reset the lamp hours in the menu.
Air Filter
Length of time between air filter replacements depends on the
environment in which the VideoWall is operated. Air filter cleanliness
should be periodically checked and the air filter replaced when dirty, at
a minimum of every 3,000 hours of operation. An excessively dirty air
filter can block air flow to the optical assembly and cause excessive
heat buildup inside the VideoWall. The air filter is most easily accessed
from the rear of the VideoWall by first removing the lamp access cover.
CAUTION
Use care when removing the air filter to avoid causing
accumulated dust to fall into the optical assembly.
1. Turn off the power
Switch off the WN-5220-V using the remote and allow the
cooling cycle to complete (3 – 4 minutes) before switching
off the AC power at the rear-panel switch.
2. Unplug power cord
Remove the AC power cord from the WN-5220-V.
3. Remove screen or
To gain access to the filter from the front of the VideoWall,