User`s guide

WN-5220-V VideoWall User’s Guide
7 October 1998
Installation
Read the chapter on safety precautions before installing and
operating the WN-5220-V VideoWall.
The following table shows installation specifications for common
WN-5220-V VideoWall wall configurations.
Height x Width
Number of display units
1x1
Single
1x2
2 displays
2x2
4 displays
2x3
6 displays
3x3
9 displays
3x4
12 displays
4x4
16 displays
Screen Height, inches 30.9 30.9 61.8 61.8 92.7 92.7 123.6
Screen Width, inches 41.7 83.4 83.4 125.1 125.1 166.8 166.8
Weight, pounds 120 240 480 720 1080 1440 1920
115 Volts A/C Input
Current, amps 8 16 32 48 72 96 128
Power, watts 920 1840 3680 5520 8280 11,040 14,720
Heat, BTU/hr 2827 5655 11,310 16,965 25,448 33,931 45,241
Air Cond., tons .24 .47 .94 1.41 2.12 2.83 3.77
230 Volts A/C Input
Current, amps 4 8 16 24 27 48 64
Power, watts 920 1840 3680 5520 8280 11,040 14,720
Heat, BTU/hr 2827 5655 11,310 16,965 25,448 33,931 45,241
Air Cond., tons .24 .47 .94 1.41 2.12 2.83 3.77
Table 1