Functional Tests
Every display should be fully tested after it is repaired to verify that all features and
functions are working properly. Take a few minutes to check everything thoroughly
to insure that other problems won’t appear after you have left the customer’s site.
Prior to starting these tests make sure that the Input Levels have been properly set.
Color balance the display or make sure that the red, green and blue Color Balance
numbers are all set to 31.
Test Video
Mode
Pattern or
Image
Pass Criteria
Mechanical
Air Flow N/A Air is blowing out of the Power
Supply Access Cover and the
exhaust vent of the Lamp Access
Cover
Optical
“On” sub-pixels Any Black Less than 12 – see Optical Defect
Specification below
“Off” sub-pixels Any White Less than 10 - see Optical Defect
Specification below
Geometry/
Keystone Issues
Any Geometry Less than 2 pixel tilt across screen
Size External
source only
Geometry Image has 3 rows or columns
behind each mullion and the rest of
the image is in the viewable portion
of the screen.
Dirt/Smudges Any White None visible - see Optical Defect
Specification below
Electrical