Field Replaceable Unit Procedures
Electronics Module
The Electronics Module houses the controller board, which provides connections for all
signals entering and leaving the WN-5220-V. It also contains the microprocessor and all
control circuitry that drives the LCD. This procedure requires access to the back of the
VideoWall.
∇
CAUTION
Always switch off the WN-5220-V before connecting or disconnecting cables. Failure
to do so (“hot plugging” the cables) can destroy the controller board.
1. Turn the lamp off
Switch off the WN-5220-V using the remote and allow
the cooling cycle to complete (3 – 4 minutes) before
switching off the AC power at the rear-panel switch.
2. Remove power cord
Remove the AC power cord from the WN-5220-V.
3. Remove input cables
Remove any signal cables from the rear panel of the WN-
5220-V.
4. Remove the screen
Only if servicing from the front.
5. Disconnect the LCD
cable
On the electronics module, disconnect the LCD ribbon
cable, using a small flat-blade screwdriver. Carefully lift
a tab on each end of the connector and removing the
cable (note that the cable’s conductors face the front of
the WN-5220-V for reinstallation).
6. Disconnect the
Interlock/Fan connector
Disconnect the 4 pin Interlock/Fan connector part of the
DC Power Wiring Harness.
7. Disconnect the DC power
connector
8. Undo the 2 thumb screws
The 2 screws are captive and do not separate from the
module. One screw is near the
p
ower su
pp
l
y
and the