Product data
WN-5220-V Module Level Service Guide
15
Test Patterns
Brings up the following sub-menu that generates the full-screen patterns:
Test Patterns
[X] Off
[ ] White
[ ] Black
[ ] 50% Gray
[ ] Red
[ ] Green
[ ] Blue
[ ] Geometry
Most of these are self explanatory.
Off – allows the source data/video to be displayed
Geometry- displays a black background with a white grid pattern. The outside edge of
the image is a white line that is one line wide. Six pixels (lines) in from the edge is
another rectangle that is one line wide. This pattern is useful for mechanically centering
the LCD and verifying geometry issues.
Gamma Disable
Changes the gamma curve that the WN-5220-V electronics use to linearize what the LCD
displays. Basically, it changes the way the color information is displayed.
OEM Select (firmware version 3e and higher)
This feature selects the OEM name that is displayed in the About menu. The default setting of 000
sets the brand name to Clarity.
Newer Electronics
(two Monitor ID knobs)
Service Menu
[ ] Lockout Disable
[ ] Test Patterns
[ ] Gamma Disable
< > OEM Select: 000
Lockout Disable
Reduces the standby-delay time from 3 minutes to 3 seconds. This can be useful when
diagnosing start-up problems. This feature should be used with caution! If the lamp has been on
and the display is turned off, it needs several minutes to cool down before attempting to re-
ignite the lamp.