Product data
WN-5220-V Module Level Service Guide
9
Preventative Maintenance
Preventive maintenance consists of replacing the air filter when it is dirty, ensuring that
the screen is clean and free of smudges or scratches, and cleaning the mirrors if they
become smudged or dusty. The projection lamp has a service life of 3,000 hours and should
be replaced at that time for trouble-free operation.
Screen
Removing the screen provides service access to other replaceable modules from the front
of the VideoWall.
∇
WARNING
The WN-5220-V VideoWall contains electrical interlocks that prevent operation when
the front screen is removed. Never operate the VideoWall with any access panels or
the front screen removed from the unit, except when required for servicing.
Operating the VideoWall with access panels or the front screen removed can expose
service or operating personnel to ultraviolet burns and high electrical voltages.
Always wear ultraviolet-blocking eyeware with side guards when servicing the
VideoWall.
1. Grasp the screen on
each side at the bottom
Pull out to separate the latch-hooks from the latches.
2. Slip fingers between the
screen frame
Slip fingers between the screen frame and the VideoWall chassis as close
to the top latches as possible and. pull the top of the screen from the
latches.
3. Using both hands…
Carefully remove the screen and set it aside. Protect it from damage.
NOTE
It may be easier to remove the screen from a VideoWall installed in a
video wall configuration by first removing screens from surrounding
units to allow hand access to the screen frame to be removed.
Improperly removing the screen can damage the screen latches.
An optional screen removal tool is available, the SRT-100. Contact
Clarity Visual or your reseller for more information.