Installation manual

-14-
13.
Program RPM:
Requires Ungo-Net Start Module.
Button 1: "Learns" the tach reference of the vehicle.
Button 2: Selects gasoline engine type.
Button 3: Selects diesel engine type.
14.
2-way Transmitter Module:
(Requires Ungo-Net 2-way Transmitter Module)
Button 1: Learns the Ungo-Net 2-way module ID
Button 2: Learns the 2-way transmitter ID. Once the remote programming
routine has been entered, press button 1 on each FM transmitter (maximum 2).
14.2 Entering Installer Programming
1. Turn the ignition ON.
2. Within 5 seconds, press the Valet/Override button 5 times.
The siren will chirp, indicating that Installer Programming has been entered.
3. Press the Valet/Override button the number of times equal to the Parameter to
be changed.
The siren will chirp each time the Valet/Override is pressed.
4. Within 5 seconds, press the transmitter button corresponding to the desired
operating mode that Parameter.
The siren will chirp corresponding to the button depressed.
5. When finished, turn the ignition OFF to save changes.
14.3 Default Reset for Installer Programming
1. Turn the ignition ON.
2. Within 5 seconds, press the Valet/Override button 5 times.
The siren will chirp, indicating that Programming has been entered.
3. Press transmitter button 3.
The siren will chirp 6 times indicating the reset signal has been received, and
Installer Parameters have been reset to factory default.
MS2106 install.qxd 6/25/2003 10:53 AM Page 14