4.8 Spectrum Mask
Spectrum of transmission signal from external antenna port of JX-4000F-
S complies with spectrum mask shown in Figure 4.8. The example shows
acceptable spectrum. This specification is applied at room temperature.
Figure 4.8
Measurement conditions of the spectrum:
1. Using spectrum analyzer connected directly to external port of JX-4000F-S.
2. Spectrum Analyzer Settings
l Center Frequency : 2436.070 MHz
l Span : 150 MHz
l Reference Level : 20 dBm
l Detection : Sample
l RBW : 1MHz
l VBW : 10Hz
l Scale : 10 dB/div
l Sweep Time : Auto
3. Using unit of dBm/MHz for power density.
4. Using continuous spreading transmission with pseudo-random data initiated by
sending special command to the M10 through MAU port
3
.
3