User`s manual

CLARION M10 SERIES STRUCTURE
M10 SERIES USER’S MANUAL PAGE 6
Down Converter: regenerates baseband signals from IF signals fed to the
A/D Converter.
A/D Converter: converts analog baseband signals to digital signal stream
for the MODEM.
Main µµP (Microprocessor): controls the signal flow, hardware functions,
and the protocol.
DC 6.2V port: The output of the AC adapter connects to this port. This
voltage is tightly specified. Please contact to Clarion, if you want to use
alternate power sources.
LED: indicates operating situations of the M10. Please refer to
specifications for details.
Sub µµP : controls power fed to each circuit of the M10.