Operating Instructions and Installation Instructions
15
CAM1 CAM4
CAM2 CAM3
CAM1 CAM2
4) In case of a hazard flasher trigger(TRG2+TRG3), the monitor displays CAM1~CAM4 as quad split screen. The
screen switches back when the hazard flasher trigger is switched off.
The example is set with TRG1(Reverse gear)=CAM1 / TRG2(Left turn signal)=CAM2 /
TRG3(Right turn signal)=CAM3
CAM1 CAM4
CAM3
CAM1
Screen in use TRG1 signal removed
* During the time that trigger is activated, [ ] buttons don’t work.
* In standby status if the trigger wire is activated the monitor will turn on. The screen will turn off once the
power is de-activated to the trigger wire. And the screens turns off when the trigger signal switches off.
Input TRG1 and TRG3
(trigger 1 has priority)
5) When more than two trigger signals are received at once, the monitor will display the highest priority trigger.
As triggers are removed, screen will show next highest priority trigger (see priority order below).
TRIGGER PRIORITY ORDER
TRG1(Reverse gear) > TRG2+3(Hazard flasher) > TRG2(Left turn signal) > TRG3(Right turn
signal)
NOTICE
NOTICE