User's Manual

ClareOne 45
Security & Arming settings
Secure Arming: When enabled this setting requires that the user enter a PIN to
arm the security panel.
Transmission Delay: The time in seconds that the panel waits if an alarm is
triggered before sending a transmission to the security central station.
Exit Delay: The amount of time in seconds the panel waits for a user to exit the
building before arming.
Swinger Shutdown: The number of times that the panel ignores a repeated
sensor trigger during an egress (false alarm).
Cross Zoning: This setting links 2 or more sensors together. If one of the
sensors is tripped, and another sensor in that cross zone is tripped within the set
time, an alarm is triggered.
Voice: This setting adjusts whether the panel annunciates zone statuses.
Chime: This setting enables/disables chimes for zone entry.
Tamper Enable: This setting enables/disables panel tamper.
Auto Armed Stay: This setting enables/disables the ignore armed stay defaults.
When enabled, armed away sets to arm stay if there is no egress.
To modify security and arming settings:
1. Tap Settings, and then tap User Settings/Installer Settings.
2. Enter the Master/Installer PIN, and then tap Security & Arming.
3. Tap on the field +/- icon, or Off/On buttons.