User Manual

Table Of Contents
Hydraulic System UNIWRAP TIC
72 UNI-h-Kap4 11/04
Description of function:
The total volume flow enters the flow controller via port P and flows
through the orifice plate (1).
Here the pressure difference p appears. The pressure downstream of
the orifice plate (1) is lower than the pressure upstream of it.
The flow controller keeps this p constant, even when the pressure in
port A changes. With a constant p at the orifice plate (1), the volume
flow leaving via port A and driving the wrapping table hydraulic motor is
constant.
The constant flow at output A can be adjusted to up to 6 l/min. with
adjusting screw (E). This allows continuous adjustment of the speed of
wrapping table rollers between 19 to 25 rpm.
- Low speed = large film overlap;
- High speed = small film overlap.