User Manual

Table Of Contents
TIC UNIWRAP Hydraulic System
11/04 UNI-h-Kap4 67
Key to diagram:
P Channel pump
Volume flow input.
T Return line (tank)
A Port
to the rod space of the right hydraulic cylinder.
B Port
to the ram space of the left hydraulic cylinder.
1 Ball
It is opened by the magnetic tappet (2).
When not energized, it closes port P.
2 Magnetic tappet
It is pushed down by the solenoid valve (Y139, Y140) and
opens ball (1).
7 Ram
Opens the non-return valve (734-1) or (734-2)
734-1 Lock-up valve unit non-return valve
This seals off port A and is opened by ram (4).
734-2 Lock-up valve unit non-return valve
This seals off port B and is opened by ram (4).
Y139 Open film cutters solenoid valve
is controlled by the UNIWRAP electronic module, actuates the
magnetic tappet (2) and thus opens the ball (1) = connection
from P to A.
Y140 Close film cutters solenoid valve
is controlled by the UNIWRAP electronic module, actuates the
magnetic tappet (2) and thus opens the ball (1) = connection
from P to B.