User Manual

Table Of Contents
Hydraulic System UNIWRAP TIC
60 UNI-h-Kap4 11/04
Description of function:
No volume flow flowing,
the solenoid valves are not
actuated.
Due to the two pressure springs located at the face end, spool (1) is
positioned so (see figure) that port P is shut off.
Raise tipping cradle Solenoid coil (Y136) is actuated by the UNIWRAP electronics module and
moves spool (1) to the left.
Volume flow flows from channel P via the spool gap to port A and
continues into the rod spaces of the hydraulic cylinders – the tipping
cradle is raised.
At the same time, volume flow from the piston spaces of the hydraulic
cylinders flows via port B into the tank (T1).
Lower tipping cradle Solenoid coil (Y135) is actuated by the UNIWRAP electronics module and
moves spool (1) to the right.
Volume flow flows from channel P via the spool gap to port B and
continues into the piston spaces of the hydraulic cylinders – the tipping
cradle is lowered.
At the same time, the volume flow from the rod spaces of the hydraulic
cylinders flows via port A into the tank (T).