User Manual
Table Of Contents
- Technical Systems Hydraulic System UNIWRAP
- Contents
- 1 Hydraulic circuit diagram
- 1.1 Hydraulic circuit diagram up to serial no.: 72600130
- 1.2 Hydraulic circuit diagram from machine no.: 72600131, with tipping cradle service shut-off valve (631)
- 1.3 Hydraulic circuit diagram from machine no.: 72600531, with film clamping cutters flow divider (769)
- 1.4 Hydraulic circuit diagram from serial no.: 72601047, with valve combination (630, 706, 769), without 3-stage restrictor (645)
- 1.5 Hydraulic circuit diagram from serial no.: 72601047, with valve combination (630, 706, 769), with 3-stage restrictor (645)
- 2 Pre-conditions for use
- 3 Valve block
- 4 Individual components
- 4.1 Input pressure balance (763)
- 4.2 Circulation shut-off valve (Y77-2)
- 4.3 Wrapping arm control unit (Y133)
- 4.4 Tipping cradle control unit (Y135 / Y136)
- 4.5 Wrapping table control unit (Y137 / Y138)
- 4.6 Clamping cutters control unit (Y139 / Y140)
- 4.7 Flow controller (630)
- 4.8 Pressure relief valve (706)
- 4.9 Wrapping arm motor (234)
- 4.10 Wrapping table motor (235)
- 4.11 Tipping cradle service shut-off valve (631)
- 4.12 Film clamping cutters hydraulic cylinder (374)
- 4.13 Film clamping cutters flow divider (769)
- 4.14 Wrapping arm motor valve block (4)
- 4.15 3-stage restrictor
- 4.16 Valve combination (7)
- 4.17 Manifold (8)
- 0293 522.0
TIC UNIWRAP Hydraulic System
11/04 UNI-h-Kap4 55
Key to diagram:
P Channel pump
Volume flow input.
T Return line (tank)
LS LS channel.
When the tipping cradle is actuated, the load pressure acts
here. This pressure signal ends in the input pressure balance.
A Port
To the rod spaces of the hydraulic cylinders. The tipping cradle
is raised when pressure is built up.
B Port
To the piston spaces of the hydraulic cylinders. The tipping
cradle is lowered when pressure is built up.
1 Spool
Actuated by solenoid valve (6).
4 Ram
Opens the non-return valve (734-1) or (734-2)
734-1 Lock-up valve unit non-return valve
This seals off port A and is opened by ram (4).
734-2 Lock-up valve unit non-return valve
This seals off port B and is opened by ram (4).
768-3 LS signal shuttle valve
Y136 Raise tipping cradle solenoid valve
The solenoid valve moves the spool (1) to the left.
Y135 Lower tipping cradle solenoid valve
The solenoid valve moves the spool (1) to the right.