3.4 Input testing (on CCU module)
Continuity test
Ser v i c e 1 8 1
P= 0L 0 , 00 N0= 0
P0 255 N1= 0
P1 0 N2= 0
E:00000000
A:00000000 U:11 ,6
F :00000000 FFFF
12345678
Eight numeric characters are available for input diagnosis in line ā€œEā€ on page "8 / 1 (Service 1)", each of them
being assigned to one circuit.
The numeric characters may assume the following values:
0 = Circuit open or
1 = Circuit closed.
All numeric characters show the respective state independently of each other. Dependencies and switching
sequences which may occur in normal operation have no influence.
The table below applies to page "8 / 1 (Service 1)"
0 = Plug removed
Changes between 0 and 1 when sensor OK
1 = Wire ends connected
Crop humidity sensorB38 E8
1 = Plug removed
Changes between 0 and 1 when feed rake rotates
0 = Wire ends connected
Rotor speed sensorB24 E7
1 = Plug removed
Changes between 0 and 1 when feed rake rotates
0 = Wire ends connected
Drive speed sensor (red)
outside
B9 E6
1 = Plug removed
Changes between 0 and 1 when feed rake rotates
0 = Wire ends connected
Feed rake speed sensor
(green) inside
B23 E5
Changes between 0 and 1 when metering wheel
rotates
Metering wheel / bale length
sensor - signal A
B69 E4
Changes between 0 and 1 when metering wheel
rotates
Metering wheel / bale length
sensor - signal B
B69 E3
0 = Switch pushed
1 = Switch not pushed
Tying system monitoring actual
value switch
Z63 E2
1 = Twine break
0 = No twine break
Twine break left/right actual
value switch
Z11 E1
DisplayDesignationNumeric
character
Diagnosis QUADRANT 2200/ 2200 RC TIC