Output testing, continued (from module 1 no. 835024.3)
Continuity test
Ser v i c e 1 8 1
P= 0L 0 , 00 N0= 0
P0 0 N1= 0
P1 0 N2= 0
E:00000000
A
:00000000
U:11 ,6
F :00000000 FFFF
12345678
To activate this function, keep the “Minus key” pressed while in the service menu, i.e. a maximum of
eight circuits may be checked at the same time.
Eight numeric characters are available for output diagnosis in line “A” on page "8 / 1 (Service 1)" and page
"8 / 2 (Service RC)", each of them being assigned to one circuit.
The numeric characters may assume the following values:
0 = Circuit open or
1 = Circuit closed and/or solenoid coil OK.
All numeric characters show the respective state independently of each other. Dependencies and switching
sequences which may occur in normal operation have no influence.
The table below applies to page "8 / 1 (Service 1)"
0 = Circuit interrupted
1 = Solenoid coil circuit OK
Baling pressure build-up
solenoid coil
Y50 A8
0 = Circuit interrupted
1 = Solenoid coil circuit OK
Baling pressure relief solenoid
coil
Y51 A7
0 = Circuit interrupted
1 = Relay circuit OK (85 to 86)
Tying release motor relayK92 A6
0 = Circuit interrupted
1 = Solenoid coil circuit OK
Circulation shut-off valve
solenoid coil
Y77 A5
0 = Circuit interrupted
1 = Solenoid coil circuit OK
Rotor blocking solenoid coilY58 A4
No functionFree None A3
No functionFree None A2
No functionFree None A1
DisplayDesignationNumeric
character
Diagnosis QUADRANT 2200/ 2200 RC TIC
16 08/2002