User Manual

Table Of Contents
Electric System LEXION 500 TIC
3a-6 Lex-e-03a 03/05
Error code list J 1939: 3/3
620 5 V power supply
3 ECM 5 Volt sensor power supply; open circuit or short-circuit with battery +
4 ECM 5 Volt sensor power supply; short-circuit with earth
639 J1939 communication
9 J1939 communication not provided
651 Injection cylinder 1
11 1st cylinder injection – mechanical fault
652
Injection cylinder 2
11 2nd cylinder injection – mechanical fault
653
Injection cylinder 3
11 3rd cylinder injection – mechanical fault
654
Injection cylinder 4
11 4th cylinder injection – mechanical fault
655
Injection cylinder 5
11 5th cylinder injection – mechanical fault
656
Injection cylinder 6
11 6th cylinder injection – mechanical fault
678 8 V sensor power supply
3 ECM 8 Volt sensor power supply; open circuit or short-circuit with battery +
4 ECM 8 Volt sensor power supply; short-circuit with earth
679 Injection drive valve controller
11 Injection drive; valve controller driver faulty
723 Second engine speed sensor
2 Second engine speed sensor not provided
3 Second engine speed sensor circuit open or short-circuit with battery +
8 Second engine speed sensor is disturbed
11 undefined engine speed sensor error
729 Heater suction air
5 Heater suction air; open circuit
6 Heater suction air; short-circuit with earth
1135 Outside oil temperature sensor
3 Outside oil temperature sensor; open circuit or short-circuit with battery +
4 Outside oil temperature sensor; short-circuit with earth