User Manual

Table Of Contents
TIC LEXION 500 Electric System
03/05 Lex-e-M M-27
Module A51 – Radial spreader
Pin Function Component Measuring
variable
Direction Circuit
diagram no.
1 Power F66 12 V Input 13 / 19
2 Earth (GND) -31 Earth Input 6
3 --- --- --- --- ---
4 Swing in right radial spreader deflector Y177 12 V (PWM) Output 13
5 Transport position Y174 12 V Output 19
6 Radial spreader deflector drive ON/OFF Y179 12 V Output 13
7 --- --- --- --- ---
8 --- --- --- --- ---
9 --- --- --- --- ---
10 Working position /swathing position U13 12 V Input 19
11 Straw chopper deflector position
(swathing)
Z59 12 V Input 19
12
13 Electronic unit + F17 12 V Input 6
14
15 Radial spreader working/transport position Y185 12 V Output 19
16 Swing out right radial spreader deflector Y178 12 V (PWM) Output 13
17 --- --- --- --- ---
18 --- --- --- --- ---
19 --- --- --- --- ---
20 --- --- --- --- ---
21 --- --- --- --- ---
22 --- --- --- --- ---
23 Straw chopper (radial spreader)
in transport position
Z60 12 V Input 19
24 not used --- --- --- ---
25 not used --- --- --- ---
26 not used --- --- --- ---
27 Power F66 12 V Input 13 / 19
28 Earth (GND) -31 Earth Input 6
29 Radial spreader swathing position Y184 12 V Output 19
30 Swing out left radial spreader deflector Y176 12 V (PWM) Output 13
31 Swing in left radial spreader deflector Y175 12 V (PWM) Output 13
32 --- --- --- --- ---
33 --- --- --- --- ---
34 --- --- --- --- ---
35 Deflector position sensor signal B129.1 0.25-4.75 V Input 13
36 --- --- --- --- ---
37 Deflector drive ON / working position Z58 12 V Input 19
38 Electronics earth B129.1 0 V Output 13
39 CAN low - - - 6
40 CAN high - - - 6
41 Electronic unit + F17 12 V Input 6
42 Electronic unit + F17 12 V Input 6
43 --- --- --- --- ---
45 --- --- --- --- ---
46 Deflector position sensor signal B129 0.25-4.75 V Input 13
47 --- --- --- --- ---
48 Transport position U14 12 V Input 19
49 Electronics earth B129 0 V Output 13
50 --- --- --- --- ---
51 --- --- --- --- ---
52 --- --- --- --- ---