TIC LEXION 500 Electric System
03/05 Lex-e-M M-25
Module A46 – Deflector adjustment (RIO)
Pin Function Component Measuring
variable
Direction Circuit
diagram no.
R0/1 Electronic unit 5 V R28 5 V Output 12
R0/2 Electronic unit 12 V --- 12 V Output 12
R0/3 Output 1 M22 12 V Output 12
R0/4 Output 3 --- --- --- ---
R0/5 Output 2 M22 12 V Output 12
R0/6 Output 4 --- --- --- ---
R0/7 Sensor 1 R28 0.25-4.75 V Input 12
R0/8 Sensor 2 --- --- --- ---
R0/9 Earth --- --- --- ---
R0/10 Earth --- --- --- ---
R0/11 Module code 1 --- 12 V Input 12
R0/12 Module code 2 --- 12 V Input 12
R0/13 Module code 3 --- --- --- ---
R0/14 Module code 4 --- --- --- ---
R0/15 Sensor 3 --- --- --- ---
R0/16 Sensor 4 --- --- --- ---
R1/1 CAN low - - - 6
R1/2 Electronic unit F17 12 V Input 6
R1/3 Power F66 12 V Input 12
R1/4 CAN high - - - 6
R1/5 Earth - Earth Input 6
R1/6 Earth - Earth Input 6