User Manual

Table Of Contents
Electric System LEXION 500 TIC
M-16 Lex-e-M 03/05
Module A30 – Terminal
Pin Function Component Measuring
variable
Direction Circuit
diagram no.
1 Coolant level float switch Z33 Earth Input 2, 5
2 Air filter maintenance switch Z69 Earth Input 3, 5
3 Hydraulic oil pressure, level Z19, Z46 Earth Input 5, 26
4 Compressor-type air conditioner fault Z22, Z23 Earth Input 5, 38
5 Rear axle limit switch, left-hand Z38 Earth Input 5, 26
6 Straw walker jammed pushbutton Z61 Earth Input 5, 26
7 Grain tank filling level 70% microswitch Z28 Earth Input 5, 30
8 Grain tank unloading Y35 Earth Input 5, 15
9 Grain tank unloading auger tube
position limit switch
Z30 Earth Input 5, 15
10 CAN low --- --- --- 5, 6
11 Power supply 12 V (+30, K56/87a) --- 12 V Input 6
12 Power supply 12 V (+30, K56/87a) --- 12 V Input 6
13 Power supply 12 V (+30, K56/87a) --- 12 V Input 6
14 --- --- --- --- ---
15 Hydraulic oil temperature switch Z20, B123 Earth Input 5, 26
16 Parking brake switch Z12 Earth Input 5, 26
17 Brake circuit pressure Z79, Z80 12 V Input 5, 44
18 Rear axle limit switch, right-hand Z39 Earth Input 5, 26
19 Straw chopper position limit switch Z58 12 V Input 5, 19
20 Grain tank filling level 100%
microswitch
Z27 Earth Input 5, 30
21 Grain tank extension position limit
switch
Z29 Earth Input 5, 30
22 CAN high --- --- --- 5
23 Earth --- Earth Input 5
24 Earth --- Earth Input 5
25 Earth --- Earth Input 5