User Manual

Table Of Contents
Electric System LEXION 500 TIC
47a-2 Lex-e-47a 03/05
47a Work lights I
Key to diagram:
Coordinates
E11 Cab left centre work light .....................................................2-f-18
E14 Cab right centre work light...................................................2-f-18
E17 Grain tank unloading tube work light ................................... 2-j-20
E54 Railing inside left work light ................................................2-g-20
E55 Railing inside right work light ..............................................2-g-16
E63 Stubble lighting work light, left ............................................2-g-20
E63.1 Stubble lighting work light, right..........................................2-g-16
E65 Work light for working area ahead, left ................................2-f-19
E65.1 Work light for working area ahead, outside left ...................2-f-20
E65.2 Work light for working area ahead, outside right .................2-f-16
E65.3 Work light for working area ahead, right..............................2-f-17
E8 Rear left work light ..............................................................3-u-19
E8.1 Rear right work light............................................................3-u-16
K49 Road travel main relay......................................................... 4-i-20
K50 Work lights relay ..................................................................4-i-20
K59 Work lights relay ..................................................................4-i-20
K54 Work lights relay ..................................................................4-i-20
K60 Work lights relay ..................................................................4-i-20
S3 Work lights main switch .....................................................2-g-18
Measured value table:
Item Component Measured value Remark
K50 Remote control relay
50 A
95±10
(Pin 86/1 – 85/2)
(Pin 87/5 – 30/3)
K54 Remote control relay
15 A
30 A
95±10
(Pin 86/1 – 85/2
(Pin 87a/4 – 30/3)
(Pin 87/5 – 30/3)
K59
K60
Remote control relay
40 A changeover
contact
90±10
(Pin 86/1 – 85/2)