User Manual

Table Of Contents
TIC LEXION 500 Electric System
03/05 Lex-e-M M-7
Module A12 - Speed monitor (DZW)
Pin Function Component Measuring
variable
Direction Circuit
diagram no.
1 Front attachment speed + Y90 12 V Output 18
2 Earth (GND) -31 Earth Input 6
3 CAN high - - - 6
4 Chopper circuit signal
(chopper operating hours)
Z58 12 V Input 19
5 Feed rake conveyor speed signal B12 0.4 V - 4.6 V Input 25
6 Grain elevator speed signal B21 0.4 V - 4.6 V Input 25
7 Rotor / finger roller speed signal B24/B74 0.4 V - 4.6 V Input 25
8 Uni-spreader speed signal B27 0.4 V - 4.6 V Input 25
9 --- --- --- --- ---
10 --- --- --- --- ---
11 Concave position signal B30 0.25 - 4.75 V Input 8
12 Concave clearance + Y18 12 V Output 8
13 Concave clearance - Y17 12 V Output 8
14 Front attachment speed - Y89 12 V Output 18
15 Electronic unit F4 12 V / 1 A Input 6
16 CAN low - - - 6
17 --- --- --- --- ---
18 Returns speed signal B29 0.4 V - 4.6 V Input 25
19 Chopper speed / uni-spreader speed
signal
B28 0.4 V - 4.6 V Input 25
20 Power F16 12 V / 7.5 A Input 8, 18
21 --- --- --- --- ---
22 --- --- --- --- ---
23 --- --- --- --- ---
24 --- --- --- --- ---
25 Reverse front attachment S57 12 V Output 17