TIC LEXION 500 Electric System
03/05 Lex-e-30a 30a-3
Description of function:
Grain tank extension
(electric)
With the grain tank extension switch (S29), one of the relays K31 or K32
is actuated to open or close the grain tank. Depending on the sense of the
rotation, the grain tank extension electric motor (M9) is supplied with earth
by one of the relays K31/K32 on pin 87a, whereas the other relay,
K32/K31, switches the voltage on pin 87.
Grain tank full indicator /
Warning beacon
The earth signal of the 70% microswitch (Z28) and 100% microswitch
(Z27) is displayed as a corresponding message on the terminal (A30).
If the 70 % full signal is activated via warning beacon (E47a/b) through
switch (S40), the warning beacon is activated via microswitch (Z28) and
relay K62.