Description of function:
2/2
Reel drive pump basic
setting
- hydraulic In the basic setting, the axial piston pump (213) must be set to zero
delivery using the screw E.
- Engage front attachment
- Start diesel engine
- Engage threshing mechanism
- Front attachment ON
- Turn in screw S on the reel speed slow solenoid valve (Y96) – the
ram retracts – the pump swings to „zero delivery“
- Adjust reel speed to zero using screw E
- Complete machine again
- electric In the basic position of the reel speed control variable-displacement pump
sensor (B73), ensure that with the piston fully retracted (pump fully
swivelled back), the signal voltage must be 0.5 V (± 0.1 V).