User Manual

Table Of Contents
Electric System LEXION 500 TIC
20a-2 Lex-e-20a 03/05
20a Front attachment raise/lower, cross levelling
Key to diagram:
Coordinates
A8 AUTOCONTOUR module (CAC) ........................................ 2-i-20
DO Master valve diode PCB...................................................... 4-i-20
DS Diagnosis plug (63-pin) VIA................................................. 3-i-20
K5 Front attachment raise relay................................................ 4-i-20
K6 Front attachment lower relay............................................... 4-i-20
K7 Left-hand cutterbar cross levelling relay ............................. 4-i-20
K8 Right-hand cutterbar cross levelling relay ........................... 4-i-20
K49 Road travel main relay ........................................................ 4-i-20
S38a Front attachment raise multifunction pushbutton switch .... 4-g-17
S38b Front attachment lower multifunction pushbutton switch ... 4-g-17
S45 VARIO cutting table adjustment switch .............................. 4-g-17
S46 Cutterbar cross levelling switch (manual) .......................... 4-g-17
S69 Cross levelling / table adjustment function
pre-selection switch............................................................ 3-h-17
X8 Ground speed control lever connector ............................... 4-h-17
XE Feed rake conveyor connector........................................... 5-g-19
Y67 Solenoid coil
AUTOCONTOUR cross levelling, left.................................. 7-f-17
Y68 Solenoid coil
AUTOCONTOUR cross levelling, right ............................... 7-f-17
Y85 Raise front attachment solenoid coil .................................. 5-n-20
Y87 Lower front attachment solenoid coil.................................. 5-n-20
Measured value table:
Item Component Measured value Remark
K5
K6
K7
K8
Remote control relay
15 A
30 A
95±10 " (Pin 86/1 – 85/2)
(Pin 87a/4 – 30/3)
(Pin 87/5 – 30/3)
Y67
Y68
Y85
Y87
Solenoid coil 3.8 A
3.2 "
See inscription