TIC LEXION 500 Electric System
03/05 Lex-e-19a 19a-3
Description of function:
Swathing flap With the road travel circuit unlocked and only when the threshing
mechanism is disengaged, the switches (U13/U14) for adjusting the
swathing flap and consequently the corresponding solenoid coil
(Y74 and/or Y75) are supplied with power.
The master valve (Y77) is also actuated via the diode PCB (DO) in
parallel with the solenoid coils (Y74/Y75) because this function requires
that pressure is built up in the system.
Straw chopper circuit The relay K49 must be actuated by unlocking the road travel switch (S52)
and the limit switch (Z58) must be closed in working position as pre-
conditions for the straw chopper drive.
The threshing mechanism clutch switch (S25) controls relay K14 and thus
activates the power supply for solenoid coil (Y21) of the threshing
mechanism clutch (see also diagram 4).
When the limit switch (Z58) is closed, the solenoid coil (Y76) for the straw
chopper drive is also actuated in the working position of the straw
chopper.
Straw chopper speed
monitoring
When the straw chopper is activated, the speed monitor module (A12)
receives the start signal for monitoring the straw chopper speed from
sensor (B28).