User Manual

Table Of Contents
Electric System LEXION 500 TIC
13b-2 Lex-e-13b 03/05
13b Straw and chaff spreader, radial spreader
Key to diagram:
Coordinates
A10 Fieldwork computer module (BIF/CAB) ............................... 2-i-20
A51 Radial spreader module...................................................... 5-s-18
B129 Deflector position right sensor ............................................6-u-17
B129.1 Deflector position left sensor ..............................................6-u-19
K49 Road travel main relay......................................................... 4-i-20
R27 Spreading width potentiometer (set value).........................4-h-17
R29 Spreading direction potentiometer (set value)....................4-h-17
X7 Connector
deflector adjustment / uni-spreader .................................... 5-s-17
X27 Connector (deflector adjustment module A46 – RIO) .........4-t-18
Y175 Swing in left radial spreader deflector ................................ 5-s-19
Y176 Swing out left radial spreader deflector .............................. 5-s-19
Y177 Swing in right radial spreader deflector .............................. 5-s-19
Y178 Swing out right radial spreader deflector............................ 5-s-19
Y179 Solenoid valve
Radial spreader deflector drive ON/OFF ............................ 5-s-19
Measured value table:
Item Component Measured value Remark
B129 Sensor 12 V
0.25 V - 4.75 V
(Pin 1-2)
(Pin 1-3)
R27
R29
Potentiometer
4.70 K
1.7 - 6.4 K
(Pin A - E) coil
(Pin S - E) slider
Y175
Y176
Y177
Y178
Solenoid coil
2 - 3
proportional
Y179 Solenoid coil
5 - 6
I - 0