User Manual

Table Of Contents
Electric System LEXION 500 TIC
13a-2 Lex-e-13a 03/05
13a Straw and chaff spreader, uni-spreader - LEXION 580
Key to diagram:
Coordinates
A10 Fieldwork computer module (BIF/CAB)............................... 2-i-20
A28 Uni-spreader module (VGS)................................................ 2-i-20
B71 Uni-spreader position sensor .............................................. 6-t-18
DS Diagnosis plug (63-pin) VIA................................................. 3-i-20
K52 Power supply relay .............................................................. 4-i-20
R27 Spreading width potentiometer (set value)......................... 4-h-17
R29 Spreading direction potentiometer (set value) ................... 4-h-17
X6 Straw chopper connector ................................................... 5-s-17
X7 Deflector adjustment / uni-spreader connector .................. 5-s-17
Y78 Uni-spreader master valve solenoid coil ............................ 7-s-18
Y83 Uni-spreader swing left solenoid coil.................................. 7-s-18
Y84 Uni-spreader swing right solenoid coil ............................... 7-s-18
Z59 Uni-spreader / baffle plate position actual value switch ..... 5-s-20
Measured value table:
Item Component Measured value Remark
B71 Sensor 12 V
0.25 V – 4.75 V
(Pin 1-2)
(Pin 1-3)
R27
R29
Potentiometer 4.70 K"
1.7 – 6.4 K"
(Pin A – E) Coil
(Pin S – E) Slider
Y78
Y83
Y84
Solenoid coil 3.8 A
3.2 "
See inscription