User Manual

Table Of Contents
Electric System LEXION 500 TIC
12a-2 Lex-e-12a 03/05
12a Deflector adjustment
Key to diagram:
Coordinates
A10 Fieldwork computer module (BIF/CAB)............................... 2-i-20
A46 RIO deflector adjustment module........................................ 2-i-20
K49 Road travel main relay ........................................................ 4-i-20
M22 Deflector adjustment motor ................................................ 6-u-16
R28 Spreading direction potentiometer (actual value)............... 6-u-16
R29 Spreading direction potentiometer (set value) ................... 3-h-17
Measured value table:
Item Component Measured value Remark
M22 Electric motor 5.6 A Max. current
R28 Potentiometer 0.2 – 5.0 K"
0.15 – 4.85 V
Coil
Signal
R29 Potentiometer 4.70 K"
1.7 – 6.4 K"
(Pin A – E) Coil
(Pin S – E) Slider