User Manual

Table Of Contents
Electric System LEXION 500 TIC
11a-2 Lex-e-11a 03/05
11a Sieve adjustment
Key to diagram:
Coordinates
A25 Sieve adjustment module.................................................... 2-i-20
DS Diagnosis plug (63-pin) VIA................................................. 3-i-20
K41 Upper sieve adjustment relay (close).................................. 4-i-20
K42 Upper sieve adjustment relay (open) .................................. 4-i-20
K43 Lower sieve adjustment relay (close).................................. 4-i-20
K44 Lower sieve adjustment relay (open) .................................. 4-i-20
K49 Road travel main relay ........................................................ 4-i-20
M12 Upper sieve adjustment motor ........................................... 6-q-18
M23 Lower sieve adjustment motor ........................................... 7-q-18
R37 Upper sieve adjustment potentiometer .............................. 6-q-18
R38 Lower sieve adjustment potentiometer .............................. 7-q-18
U6 Upper sieve adjustment switch............................................5-r-20
U7 Lower sieve adjustment switch............................................5-r-20
Measured value table:
Item Component Measured value Remark
K41
K42
K43
K44
Remote control relay
15 A
30 A
95±10 " (Pin 86/1 – 85/2)
(Pin 87a/4 – 30/3)
(Pin 87/5 – 30/3)
M12
M23
Electric motor 2.5 A max.
R37
R38
Potentiometer 0.5 - 5.2 K"
0.45 - 4.55 V
Coil
Signal