User Manual

Table Of Contents
Electric System LEXION 500 TIC
10a-2 Lex-e-10a 03/05
10a Fan variable-speed drive
Key to diagram:
Coordinates
A10 Fieldwork computer module (BIF/CAB)............................... 2-i-20
B15 Fan speed sensor.............................................................. 7--k-16
DS Diagnosis plug (63-pin) VIA................................................. 3-i-20
K14 Threshing mechanism relay ................................................ 4-i-20
K37 Fan speed adjustment slow relay........................................ 4-i-20
K38 Fan speed adjustment fast relay ......................................... 4-i-20
K49 Road travel main relay ........................................................ 4-i-20
K63 Fan speed adjustment lock relay......................................... 4-i-20
M3 Fan speed adjustment motor............................................... 5-l-16
Measured value table:
Item Component Measured value Remark
K63 Remote control relay
15 A
30 A
95±10 " (Pin 86/1 – 85/2)
(Pin 87a/4 – 30/3)
(Pin 87/5 – 30/3)
K38
K39
Remote control relay
40 A changeover
contact
90±10 " (Pin 86/1 – 85/2)
M 3 Electric motor 14 A Max. current