Service manual
PN 4237242C
3.4-2
INSTALLATION PROCEDURES
OPTIONAL TICKET PRINTERS
Figure 3.4-2 DIP Switch, SW1, Location
3. Ensure the MD II power is off.
4. Connect the Printer as shown in Figure 3.4-3. Connect the power cord last.
Figure 3.4-3 Printer Connections for a Single Printer
5. Perform a Printer self-test on the Ticket Printer as instructed under Heading D.1, EPSON
TM-290P SLIP PRINTER, and verify that all the characters print legibly.
CAUTION
Risk of damage to equipment. Turning the instrument’s power ON before connecting the Printer
to the instrument could damage the instrument. Ensure the power is OFF before connecting the Printer.
1
2
3
4
5
67
8
910
ON
SW 1
7303003A
TICKET
PRINTER
POWER
SUPPLY
7242053B
MD II
POWER LINE
CORD (AC DILUTER
TO ANALYZER)
25-PIN PARALLEL
CONNECTOR
SERIAL
PORT 2
AC
POWER
CABLE
CENTRONICS
PARALLEL
PRINTER
CABLE
SERIAL
PORT 1