Specifications

1110
Caution
<If the stop position of the second hand shifts, and it does not stop at the
0 seconds position>
If the crown is pulled out to the time correction position when the second hand is
at another position than the 0-second, 10-second, 20-second, 30-second, 40-
second or 50-second position, or if the second hand does not stop at the 10-
second interval movement stop positions due to the influence of static electricity
or physical impacts, perform the following procedure to set the correct time again.
1. Pull the crown twice to the time correction position when the second hand is
between 51 and 59 seconds.
2. Push the crown in a normal position. The second hand moves at 1-second
intervals for 10 seconds only.
• In the 10-second interval movement condition (non-power generating condi-
tion) only, 1-second interval movement will take place for 10 seconds after
the crown is pressed in.
3. Pull the crown twice again to the time correction position when the second
hand reaches the 0 seconds position.
Refer to <When the second hand is moving at 1-second intervals (generat-
ing electric power display) / 2-second intervals (insufficient recharging warning
display) / 2-second hitch movement (time setting warning display)>, and
reset the time.
<Setting the Calendar>
1. Pull the crown once to the calendar correction position.
2. While turning the crown to the left, match with the date of the day.
Idle motion will result if the crown is turned to the right.
If the date is adjusted while the time indication is between 9 PM and 1 AM,
the date may not change even on the following day.
This watch employs a 31-day dating system. For months with only 30 days
and February, the crown must be operated to correct the date on the first of
the following month.
3. Return the crown to the normal position.