Setting Instructions for Movement Caliber D200, D202, D206, D208 CONTENTS (click on a topic) 1. 2. FEATURES OF THIS WATCH a. Various warning functions i. Ascending Speed Warning ii. Depth Indication Warning iii. Battery Lifetime Forecast iv. Water Sensor Check Warning v. Abnormal Pressure Sensing Error Warning SPECIFICATIONS 3. NAME OF EACH PART a. Symbol marks indicated by the dot indicator and their meanings 4. 5. 6. 7. 8.
Return to Table of Contents 1. FEATURES OF THIS WATCH This product is a digital diver's watch that has an electronic depth meter. 1. Since a water sensor is installed, this watch start measuring the depth as soon as the user starts diving. 2. This watch measures the atmospheric temperature, as well as the water temperature while the user is diving. 3. Various log data are record while the user is diving. 4.
Return to Table of Contents 3. Battery lifetime forecast Warning system "BAT." flashes in the dot indicator window. o The watch cannot be set to diving mode. o The alarm does not sound. • The lamp does not light up. Operating condition Depth indication in diving mode or normal model o The battery reaches almost the end of its life x Countermeasures If the battery is replaced, all the diving data are deleted.
Return to Table of Contents 2. SPECIFICATIONS (subject to change without prior notice) Digital diver's watch with depth meter, thermometer, and water sensor Type Time accuracy (At normal temperature) ±20 seconds/month ±(3% of indicated value + 30cm (1ft)] max. Only when used at a fixed temperature range *Using temperature range: 10’C-40’C(50’F-104’F) Depth meter accuracy is affected by change of temperature however.
Return to Table of Contents 3.
Return to Table of Contents 4. HOW TO CHANGE THE MODE (FUNCTION) The mode of this watch is changed when the (M) (bottom left) button is pushed or the water sensor is wet with water. 5. TIME AND CALENDAR MODE In this mode, the present time and calendar are indicated. x x In the normal time mode, the LED (light-emitting diode) at the 12o'clock position flashes every hour on the hour for 3 seconds.
Return to Table of Contents 6. HOW TO SET THE TIME AND CALENDAR o When correcting the time, push the (B)(upper right) button for 2 seconds to flash the "second" in the time and calendar mode. o Push the (B)(upper right) button further to select a part to be corrected. o Correct the flashing part by pushing the (A)(lower right) button. If the year correctly set to the calendar, it is not necessary to correct the calendar at the end of each month (including the leap years).
Return to Table of Contents 7. ALARM MODE Once the alarm time is set, this watch sounds the alarm at the same time every day like an alarm clock. This sound continues for 15 seconds. Set the alarm according to the following procedure. 1. Push and hold the (B)(upper right) button for 2 seconds, and the alarm "hour" can be set (It flashes). 2. Set the alarm "hour" with the (A)(lower right) button. 3. Push the (B)(upper right) button once again, and the alarm "minute" can be set (it flashes). 4.
Return to Table of Contents If the watch is set to the "diving mode", 1) A swimming diver is displayed in the dot indicator to indicate that the watch is in the diving mode. 2) The LED flashes every 4 seconds to indicate that the watch is in the diving mode. 3) The depth is measured and indicated at the interval of 1 second. The measurement range of the depth is 1.0 m(4ft) - 80.0m(260ft). If the depth exceeds 80.0 m(260ft), "- -. –m”(“- -. –f”) is indicated, and if the former is less than 1.0 m(4ft), "0.
Return to Table of Contents [Meanings of "valid dives" and "invalid dives" used for this watch] Valid diving: Dives including a dive deeper than 1m(4ft) continued for at least 3 minutes. Example of one dive: (Valid dives) 3 minutes or longer (Valid diving) Invalid dive: Dives that does not include dives deeper than 1m(4ft) continued for at least 3 minutes.
Return to Table of Contents Examples of a valid dives and an invalid dives indicated by the watch Indication of a valid dive in the log mode. A number is indicated in the diving No. section to indicate how many dives (valid) have been performed Indication of an invalid dive in the log mode “- -“ is indicated in the diving No. Section If invalid dives are performed many times repeatedly (Skin diving, etc.
Return to Table of Contents [Change of mode indication] After valid dive is finished - Measurement and indication in surface mode are started After measurement and indication in surface mode are finished - Measurement and indication in surface mode are finished 10. LOG MODE In this mode, the data automatically recorded in the dive mode can be checked. Log data: (Can be checked in the log mode of the watch.) x Eight data of the maximum depth, diving time, month and date of diving, diving No.
Return to Table of Contents The log data are indicated, divided into the first log data and second log data. Change them over by pushing the (A)(lower right) button. First log data: Maximum depth, diving time, month and date of diving, diving No., and diving start time Second log data: Average depth, lowest water temperature, diving finish time How to call the log data Push the (B)(Upper right) button, and the recorded log data are indicated in x order from the latest one.
Return to Table of Contents 5) Set the watch so that its transfer terminal will be in contact with the central one of the three connection pins (See the figure below). *Do not touch the three transfer terminals with the bare finger. If they are touched, they may be stained to cause a transfer trouble. While the data are being transferred, the dot indicator indicates 'BUSY". If the transfer fails, the dot indicator indicates "ERR".
Return to Table of Contents 13. BATTERY LIFETIME FORECAST AND BATTERY Battery lifetime forecast x This watch has the battery lifetime forecast to notify the time to replace the battery. x If the battery comes near the end of its life, "BAT." flashes in the dot indicator window. PRECAUTION If the battery lifetime forecast operates in a mode other than the diving mode, the watch cannot be set to the diving mode.
Return to Table of Contents PRECAUTIONS ABOUT CARE AND HANDLING OF WATCHES TEMPERATURE CARE Avoid temperature extremes. Exposing your watch to high temperatures, such as placing it on the dashboard of a vehicle or use in a hot tub, may cause the watch to malfunction, shorten battery life or damage certain components. Leaving the watch in extreme cold temperatures may cause irregular timekeeping until the watch returns to normal operating temperature.
Return to Table of Contents Water Resistance The water-resistant quality of our timepieces is offered in varying degrees depending on the model. This ranges from non-water resistant models to those suitable for SCUBA diving. Water resistance of our timepieces is measured in BAR or Barometric Pressure. Each BAR of pressure is equal to 14.5 pounds per square inch of pressure. Water resistance is measured when the watch is at a static, or motionless state.