SAFETY PRECAUTIONS WARNING ● Keep the battery away from infants. If an infant swallowed the battery, meet a doctor immediately. ● Measure temperature according to directions given by a doctor and consult him (her). CAUTION ● ● ● ● Do not disassemble the thermometer. Do not pull the cord strongly. Do not splash water over the thermometer.
● CT915 records measurement results automatically. CT915 records data of up to 120 days (measurements). ● Basal body temperature recording mode or all-measurements recording mode can be selected. If the basal body temperature recording mode is selected, the temperature is recorded only one time a day. If the all-measurements recording mode is selected, all the measurement results are recorded. ● You can check the change of your body temperature by graph.
NAME OF EACH PART Sensor Display in value (Temperature, date) Probe Display in graph (Display by dots) POWER/MEASURE switch Right shift switch Cover Left shift switch SET switch Cord RESET switch Battery cover - Eng 4 -
1. Remove the battery cover Pressing the battery cover by the arrow, slide it in the direction of the arrow to remove it. 2. Set the battery Insert the rim of the battery under the battery hook with the positive side up, then push in the battery until it is fixed securely. If the battery is set correctly, the buzzer sounds and the display segments light up for 5 seconds. If the battery is slanted, the thermometer does not operate. 3. Fix the battery cover Fix the battery cover securely to the body.
SETTING ALARM, TIME, DATE, AND MODE 1. Turn the power on Push and hold the POWER/MEASURE switch for a while (about 1 second). A pip is heard and the power is turned on. 2. Turn the alarm ON/OFF 1) Push and hold the SET switch for a while (about 1 second). The screen for setting the alarm appears. 2) Push the right (s) or left (t) shift switch to display the bell mark ( ). If the shift switch is pushed again, the bell mark ( ) disappears. While the bell mark ( ) is displayed, the alarm is ON.
1) The alarm time is displayed and the “minute” blinks. 2) Push the right (s) or left (t) shift switch to set the “minute”. If the shift switch is pushed and held, the number changes fast. If the right (s) shift switch is pushed the number increases. If the left (t) shift switch is pushed the number decreases. 3) Push the SET switch to set the “minute”. The item to be set next blinks. 4. Set the “hour” of the alarm time 1) The alarm time is displayed and the “hour” blinks.
6. Set the “hour” of the present time 1) The present time is displayed and the “hour” blinks. 2) Set the “hour” by the operation in 3. 2) above, then push the SET switch to set the “hour”. 7. Set the “day” of the present date 1) The present date is displayed and the “day” blinks. 2) Set the “day” by the operation in 3. 2) above, then push the SET switch to set the “day”. 8. Set the “month” of the present date 1) The present date is displayed and the “month” blinks.
all-measurements recording mode. If the “LADY” mark is displayed, the thermometer is in the basal body temperature recording mode. In this mode, the basal body temperature measured for the first time on each day is recorded. If the “LADY” mark is not displayed, the thermometer is in the all-measurements recording mode. In this mode, all the measured temperatures are recorded. 1) Push the right (s) or left (t) shift switch to turn on (or off) the display of “LADY”.
BASAL BODY TEMPERATURE RECORDING MODE 1. Remove the probe from the body 1) Open the cover and push the rear end (left end) of the probe lightly to remove the probe from the hook. 2) Unwound the cord from the body. 2. Measure the basal body temperature ■ Method of measuring basal body temperature (at a regular time once a day) 1) The alarm buzzer wakes you. 2) Push any one of the switches. The alarm buzzer stops after about 30 seconds automatically.
* If the POWER/MEASURE switch is pushed and held for a while (about 1 second), the power is turned off. When displaying the measure screen while the power is turned on, push and release the POWER/MEASURE switch quickly. 3) Place the probe under your tongue. (See “How to measure basal body temperature correctly” on page 20.) Apply the probe tip (sensor) to the groove at the center of the underside of your tongue and close your mouth lightly.
* The measure mark indicates how many minutes have passed after measurement is started as shown below. Start of measurement After 1 minute After 2 minutes After 3 minutes 3. Store the probe in the body 1) Wipe off saliva with tissue paper, etc. 2) Wind the cord clockwise onto the body by 2 turns and a half. 3) Fix the probe to the hook with a click and close the cover.
the power. If the POWER/MEASURE switch is not pushed, the record display screen appears automatically and the power is turned off 30 more seconds after. the basal body temperature recording mode, the temperature mea* In sured for the first time on each day is recorded automatically, but the temperatures measured for the second time and after on the same day are not recorded automatically.
ALL-MEASUREMENTS RECORDING MODE 1. Remove the probe from the body 1) Open the cover and push the rear end of the probe lightly to remove the probe from the hook. 2) Unwound the cord from the body. 2. Measure the body temperature ■ Method of measuring body temperature (Allmeasurements recording mode) 1) Push and hold the POWER/MEASURE switch for a while (about 1 second) to turn on the power. Fix the probe to the hook with a click and close the cover.
* If the POWER/MEASURE switch is pushed and held for a while (about 1 second), the power is turned off. When displaying the measure screen while the power is turned on, push and release the POWER/MEASURE switch quickly. * To change the basal body temperature recording mode ( LADY is displayed) to the all-measurements recording display ( LADY is not displayed), repeat the operation of “Setting alarm, time, date, and mode” (on pages 6-10) from the first, then select the all-measurements recording mode.
5) In the all-measurements recording mode ( LADY is not displayed), all the measured temperatures are recorded automatically. * Even in the basal body temperature recording mode ( LADY is displayed), you can measure your body temperature by the above method. Your body temperatures measured after your basal body temperature is measured are not recorded, however. 3. Store the probe in the body 1) Wipe off saliva with tissue paper, etc. 2) Wind the cord clockwise onto the body by 2 turns and a half.
● You can check the change of your body temperatures in 31 days (31 measurements) at a glance. 1) Push and hold the POWER/MEASURE switch for a while (about 1 second) to turn on the power. (The record display screen appears.) 2) The temperatures recorded up to now are displayed in graph on the lower graph display unit. In the upper value display unit, the temperature and the date of the blinking bar are displayed alternately.
3) Move the graph forward or in reverse with the right (s) or left (t) shift switch and check the temperature and date of each bar displayed on the value display unit. * If the SET switch is pushed, the unit of the vertical axis of the graph changes (0.05°C or 0.2°C). Select either unit to check the change of your body temperature. [Unit: 0.05°C] [Unit: 0.2°C] SET Detailed graph in the range of 1.
This thermometer can record data of up to 120 days (measurements). If the temperature is measured more, the past records are deleted automatically in order from the oldest one. It is recommended that you should take notes of important data.
HOW TO MEASURE BASAL BODY TEMPERATURE CORRECTLY ● Measure temperature at regular time every morning Measure your basal body temperature at regular time every morning as long as possible. Measure immediately after waking, before getting out of bed, moving, or stretching. Accordingly, prepare the thermometer by the bed. ● Measure correctly under tongue Place the sensor under your tongue and fit it to the base of your tongue and close your month.
■ How to make personal mark “ ” You can make a personal mark for your menstrual period, etc. for convenience. 1. Push and hold the POWER/MEASURE switch for a while (about 1 second) to turn on the power. (The record display screen appears. 2. Move the graph forward or in reverse with the right (s) or left (t) shift switch and to select a date on which you want make a personal mark. 3. Push both right (s) and left (t) shift switches simultaneously and momentarily, and the personal mark “ ” blinks.
■ Method of adjusting display contrast 1. Push and hold the POWER/MEASURE switch for a while (about 1 second) to turn on the power. 2. Push and hold both right (s) and left (t) shift switches simultaneously for a while (about 1 second), and the display contrast adjustment screen appears. 3. To heighten the contrast, push the right (s) shift switch. To lower the contrast, push the left (t) shift switch. The contrast can be adjusted to 5 levels. 4.
1. Push and hold the POWER/MEASURE switch for a while (about 1 second) to turn on the power. 2. Push and hold both right (s) and left (t) shift switches simultaneously for a while (about 1 second), and the display contrast adjustment screen appears. 3. Push the SET switch, and the trumpet mark is displayed. 4. Push the right (s) or left (t) shift switch to display the ON (or OFF) mark of the switching sound. If you do not need the switching sound, select the OFF mark. 5.
■ Method of deleting the data 1. Push and hold the POWER/MEASURE switch for a while (about 1 second) to turn on the power. 2. Push and hold both right (s) and left (t) shift switches simultaneously for a while (about 1 second), and the display contrast adjustment screen appears. 3. Push the SET switch. After checking that the trumpet mark is displayed, press the SET switch again. 4.
SFunction of notifying lowering of battery voltage Lighting of battery mark: The battery voltage is lowering. Replace the battery immediately. Blinking of battery mark: The battery mark blinks for 4 seconds. The battery is almost dead. Replace it as soon as possible. Display condition: If the display is faint or cannot be read, replace the battery as soon as possible. * Since the battery attached to the purchased thermometer is for monitoring, it may be used up before the standard life.
BASAL BODY TEMPERATURE The body temperature of an adult woman becomes low and high regularly after each ovulation period. That is, the body temperature keeps low until an ovulation period, then becomes high after the ovulation period. It lowers again after the menstruation. The difference between the high temperature and low temperature is less than 1°C.
English N Basal body temperature graph High temperature period Ovulattion Day Low temperature period [Precaution] The change of the basal body temperature depends on each woman. When using the basal body temperature graph, record the basal body temperature continuously for at least three months and consult your doctor.
PRECAUTIONS Observe the following precautions to prevent a malfunction and a trouble. 1. Do not use the thermometer for any purpose other than measurement of the body temperature. 2. Do not splash water over the body. 3. Do not bring the thermometer near strong static electricity, radio wave, magnet, or TV 4. Do not use a cellular phone near the thermometer. 5. Do not bite the probe strongly. 6. Do not pull the cord more than necessity or swing the body with the cord. 7.
15. Do not store the thermometer in a place where it may be badly affected by atmospheric pressure, temperature, humidity, ventilation, sunlight, dust, salt, air containing sulfur, etc. or where chemicals are stored or gas is produced. 16. Protect the thermometer from vibrations and impacts (during transportation, too). 17. Do not mistake the polarities of the battery. 18. Do not use the thermometer together with another device. 19. If any trouble is found in the thermometer, turn off the power.
HOW TO CLEAN ● Wipe the body and cord with a cloth soaked in neutral detergent. (Since the body and cord are not water-resistant, take care extremely.) ● Wipe the probe and sensor with a cloth soaked in disinfectant alcohol or neutral detergent. ● Since the probe and sensor are water-resistant, they can be washed in water. Take care extremely, however, that water will not be splashed over the body and cord.
Nothing is displayed Is battery set correctly? See page 5. Is contrast adjusted properly? See page 22. Is battery normal? See page 25. is displayed (Error) Measure again. See pages 10 and 14. is displayed Cool down probe, then measure again.
RATING AND SPECIFICATIONS Measuring method Temperature sensor Display method Actual measurement Thermistor Display in value: 4-digit LCD (Mm. unit: 0.01) Display in graph: Bra graph of data of 31 days (measurements) [Detailed graph (Unit: 0.05°C), Wide graph (Unit: 0.2°C)] Measurement range 32.00°C - 42.00°C Measurement accuracy ±0 05°C (In range of 35.00°C - 38.00°C) ±0.
WEEE If you want to dispose this product, do not mix with general household waste. There is a separate collection systems for used electronics products in accordance with legislation under the WEEE Directive (Directive 2002/96/EC) and is effective only within European Union. Reference European standard: This products complies with EC instructions 93/42/EEC. (Medical Device Directive) and with the following standards: EN 12470-3.