Specifications

— 11 —
[In case of DC type]
1. Make sure the power supply for the opposite equipment to be connected is
OFF.
2. Prepare the power supply that can supply the supply voltage and current
capacity designated in the specifications ((DC 24 V ±10%, 1.2 to 2.1 A (9 A or
more at peak current).
3. Pass ferrite cores one by one while checking the pin number of the wiring
cable for connection to the opposite equipment. In case of open type ferrite
core, connect it after wiring has been completed. For pin numbers, refer to
“5.4 Power Supply and Interface Connector Specifications”. Be sure to use
the Ferrite core if you make the cable by yourself.
Wiring cable DC type
Opposite equipment
4. After making sure the printer power is off, fix the power connector board
with two places screws.
5. Connect the power supply and the interface connector to the printer while
making sure the connector is oriented correctly.
5. Connect the printer FG terminal to ground. Be sure to make this connection
to prevent noise, static charge, etc. Firmly make this connection using the
terminal screw at the rear of the printer.
FG terminal
Ferrite core
Opposite equipment
(ex. Parallel)