Feature Parameters
21. Operation switches Power switch 1, LF switch 1
22. Sensors and error monitoring Paper end sensor, Open cover sensor,
Head temperature, Low battery
23. Power consumption Idle - approximately 2W
When printing - approximately 15W
24. Battery Battery type: Li-ion battery pack
Cell Voltage: 3.7 V
Number of cells: 2
Battery pack voltage: 7.4 V
Battery pack capacity: 2000 mAh
25. Battery charging time Approximately 3 hours by main unit + AC adapter
26. Maximum lines printed with 40,000 lines
fully charged battery (At temperature 20°C, standard setting, alphanumeric
slide pattern printing. The number of lines may be changed
by such condition as temperature, etc.)
27. Power supply monitoring Auto Power OFF (programmable - from 1 to 60 sec.)
Low battery monitoring included.
28. AC Adapter Model: 10AD-JU (for Japan, USA, and Canada)
10AD-E (Europe)
Input voltage 90 V - 264 V AC
Output voltage 9.0 V DC 1.0 A
29. Operating Environment Temperature: 5 – 40°C
Humidity: 35 – 80% RH (No dew condensation)
30. Storage Environment Temperature: –20 – 60°C
Humidity: 10 – 90% RH (No dew condensation)
31. Reliability Print head: 50,000,000 pulses or 50km
(Normal temperature, 12.5% density, rated energy)
Mechanism: 15,000,000 lines
32. Safety standard and EMI UL, C-UL, TUV, GS, CE Marking
FCC Class B, VCCI Class B
33.Dimensions 116 (W) × 104 (D) × 63 (H) mm
(50 mm paper cover + Mag stripe reader)
34. Weight Approx. 370 g (with battery and belt clip without paper)
35. Options Serial Cable, Mag Stripe card reader (Factory option)