Service manual

CMP-10 Service Manual
CMP-10 Rev. 1.00 P 13/41Date: 2002.07.25
9. Removing the Operational Panel PCB
(1) Unscrew the two screws and detach the Operational Panel PCB from the plastic panel.
3.2 Reassembly Procedure
Reassemble the disassembled parts in the reverse order of the disassembly procedure described in 3.
CAUTION:
1. Route the cables very carefully so that they will not be caught.
• The flat cable should be located on the board side.
2. Tighten the screws firmly, but avoid tightening them too hard.
3. Use only the attached screws. There are several kinds of screws used. If they are unscrewed, be sure
to put them back in their original places.
4. After reassembly, be sure to check prior to turning on the power.