Instruction manual

Before Operation
30
5 System Maintenance Mode
1 Native
Normally NativeON is used. See the Command Reference for details.
2 Feed amount
See the Command Reference for details.
3 Command code
Normally CmndSTD is used. See the Command Reference for details.
4 For adjustable sensor, the voltage setting must be done each time AJSensOF is
changed to AJSensON, and vice versa.
5 Voltage setting
In the voltage setting, adjust the paper gap and black line adjustment controls
so that the voltages of both PE and BL displayed on the LCD screen can
read 3.0V to 3.3V.
1. Set the liner (glassine paper) only that has been removed from the label.
(For the black line paper, position the black line so that it does not come to th
e paper sensor.)
2. Set each level to 3.0V to 3.3V with the controls.
Paper gap sensor adjustment control
Black line sensor adjustment control